UNIQUE TESTING
FACILITY
D & H INDIA has taken
the lead in setting up an adequate testing facilities in the Quality
Controls testing labs such as
(a) Installation of SPECTRO
TESTING MACHINE For quick and accurate test result.
(b) Diffusible Hydrogen testing of weld metal by Mercury method
as per ISO 3690.
(c ) Determination of moisture content in flux coating as per
AWS.
(d) Corrosion testing as per ASTM A-262 Standard.
(e) Installation of single stroke V-Notch cutting. Machine for
impact test specimens.
(f) Profile Projector to check accuracy of Notch Profile
(g) Impact testing at -196° C by use of liquid Nitrogen.
(h) Arrangement for metallographic studies.
(i) Arrangement for tensile testing at elevated temperature.
(j) Hardness testing of all metals and Alloys.
|